TNV direct fired incinerator
Design and manufacture by using the German EN12753 safety standard and the European ED. It is used Metal Painting and Printing LED Drying:
1. For stable industrial and mining conditions with a high temperature concentration of 1.5g/M3 or above.
2. Industrial and mining conditions with requirements for thermal energy recovery and utilization.
3. Industrial and mining conditions required for the operation of independent drying rooms.
4. Special effects on projects that reduce emissions and increase production
TNV Direct Fired Incinerator Technical Parameters
1. Design and manufacture by using the German EN12753 safety standard and the
European ED
2. The special design scheme of Germany is the key basis to ensure that the
oxidation time of waste gas is> 1s and the voc removal rate reaches more than
99%
3. By preheating VOC waste gas can reduce energy consumption by 15%, the
operation cost is low, voc solvent for fuel operation, high temperature
incineration of clean air for heat utilization and recovery.
4. High-quality material selection and strict manufacturing process to ensure
that the equipment has a service life of 20 years.
5. Avoid exceeding the standard of nitrogen oxides under the special
combustion system design. Equipment maintenance cost is low, safe and durable,
with: forecast warning and safety interlock.
1 SET TNV to treat 2 production lines:
It is composed of furnace body, combustion chamber, heat exchanger, burner
and main flue regulating valve. TNV Direct Fired Incinerator working process: with a high temperature
resistance, high pressure air volume 25000 N m3/h, frequency conversion fan, two
paint oven front exhaust organic waste gas + hood wind 22000 N m3/h into the TNV
discharge high temperature 480℃ gas to 300℃ and then into the TNV Direct Fired Incinerator level 1 heat
exchanger using the burning temperature of 700℃ to 500℃ into the combustion zone
of direct combustion, so that the exhaust gas oxidation retention time is
greater than 1s, the 500℃ clean air emissions. In order to save energy developed
two kinds of heat recovery way:
1) direct heating: using TNV straight row 450℃
clean air frequency conversion fan will 8000 N m3/h direct heating oven heating
area, on the basis of the oven heating temperature set signal control fresh air
flow, security oven heat balance requirements so as to achieve the best energy
saving effect.
2) indirect heating: TNV Direct Fired Incinerator emissions of 500℃ flue gas high
temperature for 2 oven fresh air (in order to improve the room working
environment can have room air for fresh air) heating level 1 exchange to 100℃,
then the TNV Direct Fired Incinerator furnace level 2 exchanger to the 450℃ oven set heating temperature,
constant 2 oven heat source fresh air 8000 N m3/h according to the temperature
of the heating section of the oven temperature set signal control fresh air
flow, ensure the heat balance requirements of oven. When the average organic
solvent volume of the exhaust gas of the two drying rooms is 70kg / h, the
technical condition of the total gas volume of TNV is 110 N m3/h can effectively
realize the high quality drying process of the drying room.
3) Indirect heating
and direct heating shall automatically switch the operation through the
electronic control program.
Product Introduction
Introducing the TNV Direct Fired Incinerator, the ultimate solution for efficient and effective waste management. This innovative product is designed to provide a reliable and cost-effective method of disposing of various types of waste, including medical, industrial, and hazardous waste.
The TNV Direct Fired Incinerator is a direct combustion exhaust gas treatment machine that is manufactured by a leading company in China. With years of experience in the industry, the TNV Direct Fired Incinerator manufacturer has developed a product that is not only efficient but also environmentally friendly.
The TNV Direct Fired Incinerator is designed to operate at high temperatures, ensuring complete combustion of waste materials. This results in minimal emissions and a reduction in the amount of waste that needs to be disposed of. The incinerator is also equipped with advanced technology that allows for the efficient removal of harmful pollutants from the exhaust gases.
One of the key features of the TNV Direct Fired Incinerator is its versatility. It can be used to dispose of a wide range of waste materials, including medical waste, animal waste, and industrial waste. This makes it an ideal solution for hospitals, laboratories, and other facilities that generate large amounts of waste.
The TNV Direct Fired Incinerator is also designed to be easy to operate and maintain. It comes with a user-friendly interface that allows operators to monitor and control the incineration process. The incinerator is also equipped with a range of safety features to ensure that it operates safely and efficiently.
TNV Direct Fired Incinerator is a reliable and cost-effective solution for waste management. With its advanced technology, versatility, and ease of use, it is the perfect choice for facilities that need to dispose of various types of waste. Contact us today to learn more about this innovative product and how it can benefit your business.
Related products
-
NZ-03 Nano-polyester for Drilling Fluid
Contact UsNZ-03 is a multi-polymer composed of alkane sulfonate, alkyl ester, crosslinking agent. It forms nano-solid sealing material through special technology. The special functional groups on the molecular chain has strong adsorption ability, and strong adhesion properties. NZ-03 reduces pore-pressure transmission by sealing pore throats and micro-fractures due to reasonable size distribution of NZ-03 in muds. It can be used in various water-base drilling fluids. Its recommend dosage is 1.0 – 3.0% (v/v).
-
30 tons/day liquid waste +10 tons/day solid waste hazardous waste incineration device
Contact UsThis project intends to build a 30 tons/day liquid waste +10 tons/day solid waste hazardous waste incineration device for Jining Wansheng Environmental Protection Materials Co., LTD., which is used for incineration and treatment of hazardous waste produced by the factory.
-
Annual output of 120,000 tons of DMF, 20,000 tons of NMF project – waste liquid and waste gas incineration treatment system
Contact UsThis project plans to build a set of waste liquid and waste gas direct-fired incinerator. Including but not limited to construction drawing design, waste gas feeding system, waste liquid feeding system, combustion assistance and feeding system, incineration system, waste heat recovery system, denitration system, smoke exhaust system, auxiliary system, electronic control instrument system, etc.
-
KPR Zeolite Rotary Concentrator
Contact UsUnder low temperature conditions, high air volume organic waste gas passes through the KPR Zeolite Rotary Concentrator, and VOC molecules adsorb its surface.
Reviews
There are no reviews yet.