Sungrow String Inverter SG 6.0 RS
Suitable for 50Hz/60Hz grid, could be used in Asia, Africa,South America,Australia and Europe. Available for hand installation, no need for liftingmachinery assistance.
Type designation | SG5.0RS | SG6.0RS |
Input ( Dc ) | ||
Recommended max. PVinput power | 7.5 kWp | 9 kWp |
Max. PV input voltage | 600 V | |
Min.operating PV voltage/Start-up input voltage | 40 V/50 V | |
Rated pV input voltage | 360 V | |
Mpp voltage range | 40V-560 V | |
No.ofindependent MPp inputs | 2 | |
Default No. of pV strings per MPPT | 1 | |
Max. PV input current | 32 A (16 A/16 A) | |
Max. DC short-circuit current | 40A(20 A/20 A) | |
Output(AC) | ||
Rated AC output power | 5000 W* | 6000 W |
Max. Ac Output power | 5000 VA * | 6000 VA |
Rated AC output current ( at 230 V) | 21.8A** | 26.1A |
Max. AC output current | 22.8A ** | 27.3A |
Rated AC voltage | 220 V/230 V/240 V | |
AC voltage range | 154 V-276 V | |
Rated grid frequency/Grid frequency range | 50 Hz/45-55 Hz 60 Hz/55-65 Hz |
|
Harmonic (THD ) | <3 % ( at rated power) | |
Power factor at rated power/Adjustable power factor | >0.99/0.8 leading -0.8 lagging | |
Feed-in phases/Connection phases | 1/1 | |
Efficiency | ||
Max.efficiency/European efficiency | 97.9%/97.3% | 97.9%/97.5% |
Protection | ||
Grid monitoring | Yes | |
DC reverse polarity protection | Yes | |
AC short-circuit protection | Yes | |
Leakage current protection | Yes | |
Surge Protection | DC type II/AC type II | |
DC switch | Yes | |
PV string current monitoring | Yes | |
Arc fault circuit interrupter ( AFCl ) | Yes | |
PID Zero function | Yes | |
Optimizer compatibility*** | Optional | |
General Data | ||
Dimensions(W*H*D) | 410 mm*270 mm*150 mm | |
Weight | 10kg | |
Mounting method | Wall-mounting bracket | |
Topology | Transformerless | |
Degree of protection | IP65 | |
Operating ambient temperature range | -25℃ to 60 ℃ | |
Allowable relative humidity range ( non-condensing) | 0 %-100 % | |
Cooling method | Natural cooling | |
Max. operating altitude | 4000m | |
Display | LED digital display & LED indicator | |
Communication | Ethernet/WLAN/RS485/Dl(Ripple control & DRM ) | |
DC connection type | MC4(Max.6 mm²) | |
AC connection type | Plug and play connector(Max.6 mm²) | |
Grid compliance | IEC/EN62109-1/2,IEC/EN62116,IEC/EN61727,IEC/EN61000-6-2/3,EN50549-1,AS4777.2, ABNT NBR 16149, ABNT NBR 16150, UNE 217002:2020, NTS V2 TypeA,.CEI 0-21:2020,VDE0126-1-1/A1(VFR-2019 ),UTE C15-712,C10/11, G98/G99, | |
Grid support | Active & reactive power control and power ramp rate control |
Related products
-
321 Stainless Steel Tube
Contact UsGrade: 200series, 300series, 400series, etc
Standard: ASTM/DIN/GB/JIS/AISI
Surface: No.1/2B/BA/NO.4/6K/8K/HL(Hairline)/PVC
Payment: Term T/T; L/C; Western Union; Paypal
Delivery Time: 7-15 days upon receipt of the deposit
Package: Standard Export Packing or As Customers Requirement -
Titanium Alloy Coil
Contact UsWe adhere to the business philosophy of “gathering all the steel in the world and achieving stainless quality”, sincerely looking forward to the joining and cooperation of domestic and foreign merchants, new and old users, and working together to create brilliance
-
Gel & Clot Activator Tube
Contact UsGel and clot activator tube is used for blood serum biochemistry, immunology and drug testing, etc.
-
Makino Powder Extract
Contact UsLatin Name: Ranunculaceae
Synonyms:
Part of Used: Root
Specifications: 4:1
Appearance:
Application:Food Supplements/Nutritional Supplement/Functional Food/Pharmaceuticals
Reviews
There are no reviews yet.