Phoenix Contact – ESSENTIAL-PS/3AC/24DC/960W/EE – Power supply – 1018294
Primary-switched ESSENTIAL edition power supply for DIN rail mounting, input: 3-phase, output: 24 V DC / 960 W
Technical data
Input data
AC operation
|
Nominal input voltage range |
3x 400 V AC … 500 V AC |
|
Input voltage range |
3x 320 V AC … 575 V AC |
|
Input voltage range AC |
3x 320 V AC … 575 V AC |
|
Voltage type of supply voltage |
AC |
|
Inrush current |
< 20 A |
|
Inrush current integral (I2t) |
1.3 A2s |
|
AC frequency range |
45 Hz … 65 Hz |
|
Mains buffering time |
> 16 ms (3x 400 V AC) |
|
Current consumption |
3x 2 A (400 V AC) |
|
3x 1.6 A (480 V AC) |
|
|
Nominal power consumption |
1149.27 VA |
|
Protective circuit |
Transient surge protection; Varistor |
|
Typical response time |
< 1 s |
|
Recommended breaker for input protection |
10 A … 16 A (UL: 20 A) |
|
Discharge current to PE |
< 3.5 mA |
Output data
|
Efficiency |
91.5 % (at 400 V AC and nominal values) |
|
Output characteristic |
U/I |
|
Nominal output voltage |
24 V DC ±1 % |
|
Setting range of the output voltage (USet) |
22.5 V DC … 29.5 V DC (> 24 V DC, constant capacity restricted) |
|
Nominal output current (IN) |
40 A (UOUT= 24 V DC) |
|
Derating |
55 °C … 70 °C (2.5 %/K) |
|
Feedback voltage resistance |
35 V DC |
|
Protection against overvoltage at the output (OVP) |
< 35 V DC |
|
Active current limitation |
approx. 42 A |
|
Residual ripple |
< 20 mVPP |
|
Short-circuit-proof |
yes |
|
Output power |
960 W |
|
Peak switching voltages nominal load |
< 40 mVPP |
|
Maximum no-load power dissipation |
11 W |
|
Power loss nominal load max. |
87 W |
|
Connection in parallel |
yes, for redundancy and increased capacity |
Connection data
Input
|
Connection method |
Screw connection |
|
Conductor cross section, rigid min. |
0.2 mm² |
|
Conductor cross section, rigid max. |
6 mm² |
|
Conductor cross section flexible min. |
0.2 mm² |
|
Conductor cross section flexible max. |
4 mm² |
|
Conductor cross section AWG min. |
22 |
|
Conductor cross section AWG max. |
10 |
|
Stripping length |
8 mm |
|
Tightening torque, min |
0.5 Nm |
|
Tightening torque max |
0.6 Nm |
Output
|
Connection method |
Screw connection |
|
Conductor cross section, rigid min. |
0.5 mm² |
|
Conductor cross section, rigid max. |
16 mm² |
|
Conductor cross section flexible min. |
0.5 mm² |
|
Conductor cross section flexible max. |
10 mm² |
|
Conductor cross section AWG min. |
8 |
|
Conductor cross section AWG max. |
6 |
|
Stripping length |
10 mm |
|
Tightening torque, min |
1.2 Nm |
|
Tightening torque max |
1.5 Nm |
Signaling
|
Types of signaling |
LED |
|
Operating voltage display |
Green LED |
Signal output
|
Status display |
"DC OK" LED green |
|
Note on status display |
UOUT> 21.5 V: LED lights up |
Electrical properties
|
Number of phases |
3 |
|
Insulation voltage input/output |
3 kV AC (type test) |
|
1.5 kV AC (routine test) |
|
|
Insulation voltage output / PE |
500 V DC |
Product properties
|
Product type |
Power supply |
|
Product family |
ESSENTIAL POWER |
|
MTBF (IEC 61709, SN 29500) |
> 700000 h |
Insulation characteristics
|
Protection class |
I (with PE connection) |
|
Degree of pollution |
2 |
Dimensions
|
Dimensional drawing |
|
|
Width |
139 mm |
|
Height |
130 mm |
|
Depth |
190 mm |
Installation dimensions
|
Installation distance right/left |
0 mm / 0 mm |
|
Installation distance top/bottom |
50 mm / 50 mm |
Mounting
|
Mounting type |
DIN rail mounting |
|
With protective coating |
no |
Material specifications
|
Housing material |
Metal |
|
Housing material |
Aluminum (AlMg3) / sheet steel, zinc-plated |
|
Type of housing |
Steel sheet, zinc-plated |
|
Side element version |
Aluminum |
Environmental and real-life conditions
Ambient conditions
|
Degree of protection |
IP20 |
|
Ambient temperature (operation) |
-25 °C … 70 °C (> 55 °C Derating: 2.5 %/K) |
|
Ambient temperature (storage/transport) |
-40 °C … 85 °C |
|
Climatic class |
3K3 (in acc. with EN 60721) |
|
Max. permissible relative humidity (operation) |
≤ 95 % (at 25 °C, non-condensing) |
|
Shock |
15g |
|
Vibration (operation) |
< 15 Hz, amplitude ±2.5 mm (according to IEC 60068-2-6) |
|
15 Hz … 150 Hz, 2.3g, 90 min. |
Standards and regulations
|
Standard – Electrical safety |
EN 60950-1 |
|
Standard – Safety extra-low voltage |
EN 60950-1 (SELV) |
|
Approval – requirement of the semiconductor industry with regard to mains voltage dips |
SEMI F47 – 0706 (200 V AC) |
Approvals
|
CSA |
CSA-C22.2 Nr. 107.1-01 |
|
CSA-C22.2 Nr. 60950-01 |
|
|
UL approvals |
UL/C-UL listed UL 508 |
Conformity/Approvals
|
SIL in accordance with IEC 61508 |
0 |
|
Performance level according to ISO 13849 |
without |
EMC data
|
Electromagnetic compatibility |
Conformance with EMC Directive 2014/30/EU |
|
Low Voltage Directive |
Conformance with Low Voltage Directive 2014/35/EC |
|
EMC requirements for noise emission |
EN 61000-6-3 |
|
EN 61000-6-4 |
|
|
EMC requirements for noise immunity |
EN 61000-6-1 |
|
EN 61000-6-2 |
Noise emission
|
Standards/regulations |
EN 55011 (EN 55022) Class B |
Electrostatic discharge
|
Standards/regulations |
EN 61000-4-2 |
Electrostatic discharge
|
Contact discharge |
6 kV |
|
Discharge in air |
8 kV (Test Level 3) |
|
Comments |
Criterion B |
Electromagnetic HF field
|
Standards/regulations |
EN 61000-4-3 |
Electromagnetic HF field
|
Frequency range |
80 MHz … 1 GHz |
|
Test field strength |
10 V/m |
|
Frequency range |
1 GHz … 2 GHz |
|
Test field strength |
10 V/m |
|
Frequency range |
2 GHz … 3 GHz |
|
Test field strength |
10 V/m |
|
Comments |
Criterion A |
Fast transients (burst)
|
Standards/regulations |
EN 61000-4-4 |
Fast transients (burst)
|
Input |
4 kV (Test Level 4 – asymmetrical) |
|
Output |
4 kV (Test Level 4 – asymmetrical) |
|
Signal |
2 kV (Test Level 3 – asymmetrical) |
|
Comments |
Criterion A |
Surge voltage load (surge)
|
Standards/regulations |
EN 61000-4-5 |
Surge voltage load (surge)
|
Input |
2 kV (Test Level 3 – symmetrical) |
|
4 kV (Test Level 4 – asymmetrical) |
|
|
Output |
1 kV (Test Level 2 – symmetrical) |
|
2 kV (Test Level 3 – asymmetrical) |
|
|
Comments |
Criterion A |
Conducted interference
|
Standards/regulations |
EN 61000-4-6 |
Conducted interference
|
Frequency range |
0.15 MHz … 80 MHz |
|
Comments |
Criterion A |
|
Voltage |
Test Level 3 |
Voltage dips
|
Standards/regulations |
EN 61000-4-11 |
Emitted interference
|
Standards/regulations |
EN 61000-6-3 |
|
Radio interference voltage in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
|
Emitted radio interference in acc. with EN 55011 |
EN 55011 (EN 55022) Class B, area of application: Industry and residential |
Criteria
|
Criterion A |
Normal operating behavior within the specified limits. |
|
Criterion B |
Temporary impairment to operational behavior that is corrected by the device itself. |
Commercial data
|
Item number |
1018294 |
|
Packing unit |
1 pc |
|
Minimum order quantity |
1 pc |
|
Sales key |
CMP |
|
Product key |
CMB333 |
|
GTIN |
4055626501796 |
|
Weight per piece (including packing) |
3,468 g |
|
Weight per piece (excluding packing) |
3,450 g |
|
Customs tariff number |
85044095 |
|
Country of origin |
CN |
Related products
-
321 Stainless Steel Tube
Contact UsGrade: 200series, 300series, 400series, etc
Standard: ASTM/DIN/GB/JIS/AISI
Surface: No.1/2B/BA/NO.4/6K/8K/HL(Hairline)/PVC
Payment: Term T/T; L/C; Western Union; Paypal
Delivery Time: 7-15 days upon receipt of the deposit
Package: Standard Export Packing or As Customers Requirement -
DC Rooftop Mounted Vehicle Air Conditioners
Contact Us● Strong air volume, fast cooling
● Lightweight design, intelligent design
● Longer battery life, meeting the need for a full night’s sleep
● Energy saving/lightweight/quiet
● Split structure, rooftop mounted
● Energy saving and low consumption, quality assurance
● The company has passed the automotive industry IATF16949 certification -
Air conditioner ducted Powerful units with high cooling and heating capacity K48UFR-725P
Contact Us● Powerful units with high cooling and heating capacity
● Lightweight design, intelligent design
● Longer battery life, meeting the need for a full night’s sleep
● Energy saving/lightweight/quiet
● Split structure, bottom mounted
● Energy saving and low consumption, quality assurance
● The company has passed the automotive industry IATF16949 certification -
1500A Jump Starter with Air Compressor
Contact UsExperience ultimate convenience and reliability with our 1500A Jump Starter featuring a 150 PSI Air Compressor, ensuring you’re always prepared for any roadside emergency.






Reviews
There are no reviews yet.